HEFP: Hot Engines and Fire Prevention

What keeps an exhaust manifold from setting things on fire.

HEFP models the heat traveling out of a running engine's exhaust manifold, through a thermal-barrier coating, into the metal wall, and out to the air; then asks whether that outer surface ever gets hot enough to ignite spilled fuel with no spark at all. Every number below is computed live in your browser, using the same equations as the paper. Move a slider and watch it recompute.

01. Running engine

Steady-state surface temperature

Heat crosses four layers in series: gas-side convection into the coating, conduction through the thermal-barrier coating (TBC), conduction through the cast-iron wall, then convection and radiation out to the underhood air. Change any parameter below and the solver re-converges instantly.

Tgas: hotter fuel-air mix, hotter surface
h₁: how fast exhaust gas dumps heat into the wall
LTBC: yttria-stabilized zirconia coating
kTBC: lower = better insulator
h₂: airflow under the hood while running
ε: how much heat the surface radiates away; polished metal is low, oxidized/painted is high
Lmetal: cast-iron wall; thicker conducts more heat through at steady state, but also holds more heat during the soak
Bare metal wall
–°C
TBC-coated wall
–°C
Coating benefit
–°C
how much the TBC actually buys you

Steady-state comparison against the autoignition band

Paper default: bare 484.14 °C, TBC 477.50 °C, a 6.64 °C (1.4%) drop; both still above the danger band.

02. After shutdown

Post-shutdown heat soak

Turn the engine off and forced convection stops. The only things left cooling the surface are weak natural convection and radiation. Two solutions are compared: a fourth-order Runge-Kutta (RK4) numerical integration of the full T⁴ radiation term, and a linearized shortcut that freezes the radiation coefficient at its hottest value so it can be solved by hand.

T∞,soak: underhood air once parked
hnat: no fan, no ram air, just buoyancy
manifold treated as a horizontal cylinder for the correlation below; a real manifold isn't a simple cylinder, so this is an engineering approximation

T₀: defaults to the TBC steady-state above
Drops below 450 °C at
–min
Clears 311 °C (safe) at
–min
Danger window
–min
time spent inside the autoignition band

Surface temperature vs. time since shutdown

RK4 (solid) vs. linearized analytical shortcut (dashed): the shortcut diverges 68–70 °C from the true solution 12–20 minutes in, because it assumes the radiation rate never slows down.

RK4 (numerical, trustworthy) Linearized shortcut

The 311–450 °C band above is a hard cutoff on purpose — real ignition isn't. Hot-surface ignition studies on engine fluids find three zones, not a switch: no ignition well below the range, then increasing likelihood as temperature climbs, then ignition on virtually every contact once you're well into it. For engine oil specifically, published tests put "essentially never" below roughly 300 °C and "essentially always" above roughly 335 °C, with a genuinely probabilistic middle in between (Santrock, NHTSA 98-3588-193, 1998; SAE 2006-01-1013 and 2006-01-1014). This doesn't change any number on this page: the paper's fixed band is the right way to size a conservative safety margin, and every model above still uses it as-is. It's here because a probability curve is the more accurate picture of what's actually happening physically, and the transition zone shown in that research sits comfortably inside this page's own band, not outside it.

03. Is the model actually trustworthy?

Sensitivity, uncertainty, and numerical accuracy

Three separate checks, all run live: how sensitive is the answer to gas-side convection, how much does manufacturing tolerance on the coating move the result, and whether the RK4 solver actually converges at the rate it's supposed to (the one check most simulations skip).

h₁ sensitivity

Sweeping gas-side convection from 80 to 400 W/m²K. This is the lever that actually moves the temperature, more than coating thickness ever will.

Manufacturing tolerance (Monte Carlo)

±10% random variation in TBC thickness and conductivity, matching real coating-process tolerance.

RK4 grid-convergence study Does the solver actually converge at 4th order? Full dt sweep below.

A 4th-order method should quarter its error every time you halve the step size (error ∝ dt⁴, so halving dt should divide the error by 2⁴ = 16, an "observed order" of 4). Real solvers rarely show one clean regime across the whole range. This runs the actual sweep, live, against a reference solution 500×+ finer than any step tested.

Error vs. step size, log–log

Reference: dt = 0.00195s. Comparison point: t = 2048s into the soak (mid-transient, where truncation error is actually visible).

dt (s)T(2048s) predicted|error| vs. referenceobserved order

Three regimes, not one: dt ≥ 64s is pre-asymptotic (order looks too good; higher-order truncation terms haven't been dominated yet). dt ≈ 32–16s is a crossover anomaly where terms partially cancel. dt = 16→2s is the genuine asymptotic 4th-order regime, highlighted below. Below dt = 1s the error runs into float64 noise (~10⁻¹¹–10⁻¹² °C) and the order estimate degrades again.

Is the lumped-capacitance simplification valid? (beyond the paper) The RK4 soak model treats the whole wall as one uniform temperature. Cengel & Ghajar's Biot-number criterion checks whether that's actually a safe simplification.

A "lumped" model only makes sense if the wall's internal temperature gradient is small enough to ignore, i.e. the wall cools faster by convection off its surface than heat can conduct through it. The standard test (Cengel & Ghajar, Heat and Mass Transfer, ch. 4) is the Biot number, Bi = h·Lc/k: below 0.1, treating the whole body as one temperature typically introduces less than 5% error. This isn't reported in the paper; it's a live check on the paper's own modeling choice, using the current wall thickness and effective outer heat-transfer coefficient (natural convection + linearized radiation at the hottest point in the soak).

Biot number, live